GMDW 13 PLUS
GEOTHERMAL HEATING HEAT PUMP – DIRECT HEATING
METRICS (H/B/T): | 115 X 60 X 65 |
WEIGHT: | 128 |
FLOW TEMPERATURE: | 65 |
HEAT SOURCE: | GROUND-DIRECT HEATING |
DHW TEMPERATURE: | 65 °C |
VERSION: | HEAT |
FUSE PROTECTION (A): | 10 |
RATED VOLTAGE (V): | 400 |
SCOP (35°C): | 5.42 |
HEATING OUTPUT: | 11.3 |
POWER CONSUMPTION: | 2.6 |
COEFFICIENT OF PERFORMANCE: | 4.4 |
OPERATING POINT E0/W50 | |
HEATING OUTPUT: | 10,3 |
POWER CONSUMPTION: | 3,3 |
COEFFICIENT OF PERFORMANCE: | 3,1 |
OPERATING POINT E0/W60 | |
HEATING OUTPUT: | 10,2 |
POWER CONSUMPTION: | 4,1 |
COEFFICIENT OF PERFORMANCE: | 2,5 |
OPERATING POINT E4/W35 | |
HEATING OUTPUT: | 14,2 |
POWER CONSUMPTION: | 2,8 |
COEFFICIENT OF PERFORMANCE: | 5,1 |
- Compact appliance with 250 l cylinder
- For households with up to 4 residents
- Water temperature of up to 65 °C in heat pump mode
- Fully wired
- Straightforward installation
- With sensor well for third party thermostat/sensor
- With coil for external heat generators such as boilers and solar thermal systems
- Integral immersion heater as standard
- Possibility of DN 150 air duct up to 20 m
- One integral sacrificial magnesium anode as standard
- Pasteurisation circuit is part of the heat pump
- Tiptronic light controller
- Optimal heat input
Applications
DHW heating
Larder cooling
Basement dehumidification