GMWW 38 HK
HEATING HEAT PUMP WITH WATER AS THE HEAT SOURCE
METRICS (H/B/T): | 115 X 60 X 65 |
WEIGHT: | 175 |
FLOW TEMPERATURE: | 55 |
HEAT SOURCE: | WATER |
DHW TEMPERATURE: | 60 °C |
VERSION: | HEATING/COOLING, HEATING |
FUSE PROTECTION (A): | 25 |
RATED VOLTAGE (V): | 400 |
SCOP (35°C): | 5.96 |
HEATING OUTPUT: | 37.3 |
POWER CONSUMPTION: | 6.9 |
COEFFICIENT OF PERFORMANCE: | 5.4 |
OPERATING POINT W10/W50 | |
HEATING OUTPUT: | 34,4 |
POWER CONSUMPTION: | 9,7 |
COEFFICIENT OF PERFORMANCE: | 3,5 |
OPERATING POINT W10/W60 | |
HEATING OUTPUT: | - |
POWER CONSUMPTION: | - |
COEFFICIENT OF PERFORMANCE: | - |
OPERATING POINT W10/W18 | |
POWER CONSUMPTION: | 6,2 |
COEFFICIENT OF PERFORMANCE: | 6,3 |
The heat generator for the highest COPs, as an option also available with cooling function and tubular heat exchangers for greater operational reliability